BMW Group
Page 59
Documentation/ISTA User's Manual of 132
◊ Calculate test plan: starts the calculation and display of the test plan with the existing
fault memory entries and selected diagnostic symptoms (Chapter 3.5.2).
Display detail table
Fig. 3.27 "Fault details" mask
The "Fault details" mask contains supplementary descriptions on a fault code:
◊ Control unit: the name of the control unit version will be displayed.
◊ Fault memory: displays the fault code in hexadecimal form and, below this, fault location.
◊ Vehicle data: the fault status as well as details on the ambient conditions will be displayed
(if available).
The buttons in the action line have the following functions:
◊ Update: The detailed information will be reread and displayed.
◊ Close: closes the window and returns to the "Fault memory" mask.
V 1.0/2008-11-04
Copyright © BMW AG 2008