12
E90 Voltage Supply & Bus Systems
Terminal 15 Wake-up Signal Faults
The IBS recognizes wake-up line faults. The IBS can detect a wake-up line error under
the following conditions:
• DME “ON”
• Terminal 15 “ON” (voltage high at IBS)
• Terminal 15 running via BSD
If Terminal 15 at the IBS and Terminal 15 via the BSD are not equal, a fault is indicated in
the BSD line or an IBS Fault.
IBS Wake-up
The IBS constantly monitors the SoC, even when the vehicle is a sleep, a wake-up signal
is sent to the DME via the BSD if the SoC falls below the preset threshold. Upon obtain-
ing the wake-up from the IBS, the DME obtains information on the current SoC of the
battery from the IBS and requests that auxiliary electrical loads be switch off.
The IBS may only wake-up the vehicle once during a key off cycle, once awakened the
vehicle will again return to the sleep mode.